configured limit or use OpenSSL 1.1. Nothing we can do for older
versions.
+JH/14 For the "sock" variant of the malware scanner interface, accept an empty
+ cmdline element to get the documented default one. Previously it was
+ inaccessible.
+
+JH/15 Fix a crash in the smtp transport caused when two hosts in succession
+ are unsuable for non-message-specific reasons - eg. connection timeout,
+ banner-time rejection.
+
+JH/16 Fix logging of delivery remote port, when specified by router, under
+ callout/hold.
+
+PP/06 Repair manualroute's ability to take options in any order, even if one
+ is the name of a transport.
+ Fixes bug 2140.
+
+HS/01 Cleanup, prevent repeated use of -p/-oMr (CVE-2017-1000369)
+
+JH/17 Change the list-building routines interface to use the expanding-string
+ triplet model, for better allocation and copying behaviour.
+
Exim version 4.89
-----------------