X-Git-Url: https://git.exim.org/exim.git/blobdiff_plain/31f90faace8d68c41bdaa16d1079da39e0529e64..3875eb02bed6a9fb66e76879698d89109c308ac6:/test/scripts/0000-Basic/0217 diff --git a/test/scripts/0000-Basic/0217 b/test/scripts/0000-Basic/0217 index c47ae5c9e..dceb1d2a9 100644 --- a/test/scripts/0000-Basic/0217 +++ b/test/scripts/0000-Basic/0217 @@ -1,4 +1,5 @@ # PIPELINING (client: errors, etc) +munge peer_terminated_conn need_ipv4 # server PORT_S @@ -36,7 +37,7 @@ RCPT TO 250 OK *sleep 2 **** -exim -odi a b c +exim -odi e f g . **** # Temp error on MAIL @@ -56,7 +57,7 @@ DATA QUIT 250 OK **** -exim -odi a b +exim -odi h i . **** # Perm error on MAIL @@ -76,7 +77,7 @@ DATA QUIT 250 OK **** -exim -odi a b +exim -odi j k . **** # All get temp errors @@ -96,7 +97,7 @@ DATA QUIT 250 OK **** -exim -odi a b +exim -odi l m . **** # All get perm errors @@ -116,7 +117,7 @@ DATA QUIT 250 OK **** -exim -odi a b +exim -odi n o . **** # Mixed temp and perm @@ -136,7 +137,7 @@ DATA QUIT 250 OK **** -exim -odi a b +exim -odi p q . **** # Perm error on DATA after good recipients @@ -156,7 +157,7 @@ DATA QUIT 250 OK **** -exim -odi a b +exim -odi r s . **** # Temp error on DATA after good recipients @@ -176,7 +177,7 @@ DATA QUIT 250 OK **** -exim -odi a b +exim -odi t u . **** # Temp error on DATA after good recipients, but in first block of a @@ -640,4 +641,342 @@ DATA **** exim -v -odi -DHAP=hosts_avoid_pipelining=127.0.0.1 w x y z **** +# Server says 452 excess-rcpts temp error after first 50 +# Exim client checks after 100 +sudo rm -fr DIR/spool/input +server PORT_S +220 Server ready +EHLO +250-OK +250 PIPELINING +MAIL FROM +250 OK +RCPT TO +250 OK 0 +RCPT TO +250 OK 1 +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK 49 +RCPT TO +452 excess 50 +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess +RCPT TO +452 excess 99 +RCPT TO +452 excess 100 +DATA +354 go +. +250 msg accepted +MAIL FROM +250 good mail +RCPT TO +250 OK 50 +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO +250 OK +RCPT TO: